Clarke 2092500 운영 및 유지보수 지침 매뉴얼 - 페이지 13
{카테고리_이름} Clarke 2092500에 대한 운영 및 유지보수 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Clarke 2092500 17 페이지. 150l engine driven air compressor
SYMPTOM
Compressor
unit runs on
and off load
more
frequently
than usual.
Compressor
unit runs 'on
load' when
no air is being
used.
Compressor's
oil
consumption
rising.
Oil in the air
delivered.
Oil level rises
although no
oil has been
put in.
Condensation
at outlet
points.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
PROBABLE CAUSE
Large amount of
condensation in air receiver.
Leaks in system
Leaks in system
Too much oil in compressor.
Leaks around crank case
Working temperature of
compressor too high because
of insufficient cooling.
Cylinder worn.
Intake air filter blocked
Sump over full
Cylinder worn
Intake air filter blocked
Condensation in oil pump.
Piping installation incorrect.
Compressor taking in air
which is too warm.
REMEDY
Drain off condensation
Regularly (Every day
before use).
Locate leaks (by means of
soapy water) and repair.
Locate leaks (by means of
soapy water) and repair.
Check oil level 2 or
3 minutes after stopping.
Contact Clarke Service
Department
Increase ventilation to air
compressor.
Contact Clarke Service
Department
Clean or replace
Reduce oil to correct level.
Contact Clarke Service
Department
Clean / Change air filter.
Compressor over
dimensioned.
Consult your local dealer
Obtain better fresh-air
supply to compressor.
13