Adaptation to different types of gas
Injectors replacement
•
Remove the pan supports.
•
Remove the burner's caps and crowns.
•
With a socket spanner 7 unscrew and remove the
injectors (Fig. 8), and replace them with the ones
required for the type of gas in use (see Table 2).
•
Reassemble the parts, following the same procedure
backwards.
•
Replace the rating label (placed near the gas supply
pipe) with the relevant one for the new type of gas
supply. You can find this label in the package of the
injectors supplied with the appliance.
Should the feeding gas pressure be different or variable
compared with the required pressure, an appropriate
pressure adjuster must be fitted on the gas supply pipe,
in compliance with the rules in force.
Adjustment of minimum level
To adjust the minimum level of the burners, proceed as
follows:
•
Light the burner.
•
Turn the knob on the minimum position.
•
Remove the knob.
•
With a thin screwdriver, adjust the by-pass screw
(see Fig. 9). If changing from natural gas to LPG,
completely tighten clockwise the screw, until a small
regular flame is obtained.
•
Finally check the flame does not go out when quickly
turning the knob from the maximum position to the
minimum position.
This procedure can easily be carried out, anyhow the
hob has been positioned or built in the working top.
Table 2: Injectors
TYPE
TYPE OF
OF GAS
BURNER
Ultra-rapid (large)
NATURAL
Rapid (large)
GAS
Semi-rapid (medium)
G 20
Auxiliary (small)
Ultra-rapid (large)
LPG
Rapid (large)
(Buthane/
Semi-rapid (medium)
Propane)
Auxiliary (small)
Ultra-rapid (large)
NATURAL
Rapid (large)
GAS
Semi-rapid (medium)
G 20
Auxiliary (small)
* for Russia only.
8
INJECTORS
NOMINAL
MARKS
POWER
1/100 mm
INPUT
KW
146
4,00
113
2,80
96
2,00
70
1,00
98
4,00
86
2,80
71
2,00
50
1,00
146
3,00
108
2,13
105
1,72
80
0,90
FO 0392
Fig. 8
Fig. 9
By-pass screw
Table 1 : BY-pass diameters
Burner
Auxiliary
Semi-rapid
Rapid
Ultra rapid
REDUCED
POWER
kW
m
1,20
0,381
0,65
0,267
0,45
0,190
0,33
0,095
1,20
0,65
0,45
0,33
1,20
0,285
0,52
0,210
0,42
0,186
0,30
0,085
Ø By-pass
in 1/100
of mm.
28
32
40
56
NOMINAL
NOMINAL
POWER
PRESSURE
mbar
3
/h
g/h
-
-
-
20
-
-
288
-
202
-
144
28-30/37
-
72
-
-
-
13*
-