2 - Air discharge towards the wall (fig. 3)
In this case the hood can only be used in suction mode.
3 - Side air discharge, Lh or Rh (fig. 4a-b).
In this case the hood can only be used in suction mode.
R
S07_04
4a
4.2 - Installation of the hood canopy C
1 - Drilling the wall
a) Using the cardboard template provided, mark on the wall the centres of holes 1 for fixing of the
hood canopy C. The centre of hole 2 for fixing the chimney, (fig. 5a) air outlet directed upwards or
towards the wall, (fig. 5b-c) air outlet to the right or left hand side, must be marked at a distance X
from the line between holes 1, obtained by measuring the extension Z of the chimney required for
installation, plus 28 mm X=Z+35-7. Using a Ø8 mm drill bit, drill the points marked in this way.
A03_05
b) When installed with the air outlet directed towards the wall (fig. 5a), it will be necessary to drill
an air ducting opening, measuring Ø120 or 150 mm, according to the diameter of the flange F
provided.
R
4b
2
1
1
ø 8
100 100
5a
105
105
2
2
1
1
5b
14
1
1
5c
3