Clarke SHHHAIR 30 운영 및 유지보수 지침 매뉴얼 - 페이지 9
{카테고리_이름} Clarke SHHHAIR 30에 대한 운영 및 유지보수 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Clarke SHHHAIR 30 17 페이지. Silent air compressor
TROUBLESHOOTING
PROBLEM
The compressor will not start,
or stops and will not start
again
The compressor does not
reach the set pressure and
overheats easily
Air pressure from the
regulator will not adjust
Compressor operating, but
no air from outlet
PROBABLE CAUSE
Bad connections
Blown fuse
Overload cutout switch has
tripped
Inlet Air Filter is blocked
NOTE: It is also possible that
you are trying to use more
air than the compressor is
capable of delivering
The diaphragm within the
regulator body is broken
Inlet air filter blocked
Pressure regulator closed
9
REMEDY
Check the electrical
connections
Replace fuse
Wait 25-20 mins before
attempting to restart
Renew oil filler/air Filter
plug
Replace regulator
Renew oil filler/air Filter
plug
Turn regulator
clockwise to set
required pressure