OUTLET PRESSURE ADJUSTMENTS

CFP9BH
1.
Pressure Adjusting Knob
2.
Lock Nut
3.
Air Outlet
4.
Bleed Hole
To adjust outlet pressure
clockwise to increase outlet pressure, anticlockwise to decrease. Tighten lock nut
(2) when correct pressure is obtained.
NOTE:
1.
When Compressor reaches cut-out pressure air will bleed from bleed hole (4).
2.
Item (3) quick fit nut can be removed if required and hose can be fitted using
1/4 BSP nut.
PORTABLE COMPRESSORS
1.
Pressure Adjusting Knob
2.
Outlet Taps
3.
Quick Fit Nuts
4.
Pressure Gauge
To adjust outlet pressure:
To increase pressure - turn knob (1) clockwise.
To decrease pressure - turn knob (1)
anticlockwise.
Outlet taps
- slide knurled section (2) away
from body to open, push towards body to
close.
NOTE: Pressure Gauge (4). Pressure shown will differ by approximately 1 bar
depending on whether the outlets are open/closed.
STATIONARY COMPRESSORS
These machines are not supplied with the facility to adjust outlet pressure. A
comprehensive range of airline accessories is available from your local CLARKE
stockist.
- slacken lock nut (2). Turn Pressure Adjusting Knob (1)
12