California Air Tools 1810C 매뉴얼 - 페이지 6

{카테고리_이름} California Air Tools 1810C에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. California Air Tools 1810C 8 페이지. 10 gallon casting pressure pot

Trouble Shooting
WARNING!
If any of the following symptoms appears during your operating, stop using the tool immediately, or
serious personal injury could result.
Only a qualified persons or an authorized service center can perform repairs or replacement of tool.
Disconnect tool from air supply before attempting repair or adjustment. When replacing O-rings or
Cylinder, lubricate with air tool oil before assembly.
PROBLEMS
Air escaping from port on
regulator cap
Pressure dropping slowly
on gauge.
Air leak at the lid gasket.
POSSIBLE CAUSES
Broken or damaged
diaphragm in regulator.
Dirty or work valve seat in
regulator.
Defective lid gasket.
Thumb screw not tight.
CORRECTION
Replace regulator
Replace regulator
Replace lid gasket.
Tighten thumb screws.