Clarke CONTRACTOR DEVIL371PD 운영 및 유지 관리 지침 - 페이지 6

{카테고리_이름} Clarke CONTRACTOR DEVIL371PD에 대한 운영 및 유지 관리 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Clarke CONTRACTOR DEVIL371PD 17 페이지. Devil quartz halogen heater

Clarke CONTRACTOR DEVIL371PD 운영 및 유지 관리 지침

ELECTRICAL CONNECTIONS

DEVIL 371PD (110V) UNIT
The 110V model is fitted with a 32 Amp, three pin industrial plug to EN 60309
and MUST be connected to a 110 volt, 1 phase 50 Hz supply through a suitably
fused isolator switch.
On no account must a 230V, 13 amp (BS1363) plug be used.
NOTE: If a portable 110V transformer is used, make sure it has a rated
capacity sufficient to take the load of the heater.
If the heater is hard wired into the electrical system, all work must be carried
out in accordance with IEE regulations.
If the plug has to be changed due to damage, a replacement should be
fitted, following the wiring instructions shown below. The old plug must be
disposed of as insertion into a 110v socket could cause an electrical hazard.
WARNING: THE WIRES IN THE POWER CABLE OF THIS PRODUCT ARE
COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE:
BLUE = NEUTRAL
If the colours of the wires in the power cable of this product do not correspond
with the markings on the terminals of your plug, proceed as follows.
• The Blue wire must be
connected to the terminal
which is marked N or
Neutral.
• The Brown wire must be
connected to the terminal
which is marked L or Live.
• The Yellow wire must be
connected to the terminal
which is marked E or Earth.
If in any doubt, consult a qualified
electrician. DO NOT attempt any
repairs yourself.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
BROWN = LIVE
YELLOW = EARTH
Plug must be BS60309 approved.
Earth
Neutral
6
Live