Clarus ZF-450 소유자 매뉴얼 - 페이지 17
{카테고리_이름} Clarus ZF-450에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Clarus ZF-450 20 페이지. Treatment systems
The blower is equipped with a safety slide switch designed to protect the motor in the event of a diaphragm rupture. If tripped, the blower
motor will not operate, but the timer will remain functional. Follow the directions below to reset the safety slide switch after the diaphragms
have been replaced. If the diaphragms are not replaced first, resetting the safety slide switch may damage it:( pg 18)
1. Turn off the blower's circuit breaker in the control panel. Ensure that the blower motor has stopped and the unit does not have power.
2.
Remove the four corner screws securing the
upper cover to the blower base and remove
the cover.(Figure 1)
3.
Remove the sound absorbing felt from
around the motor.(Figure 2)
4.
Pinch both sides of the safety slide switch
and slide it to the center position of the
switch base until it clicks into place. (Figure
3,3A,4,4A)
5.
Check that the protrusion of the switch slide is adjusted
to the position of the " " mark and the switch part of the
micro switch is pressed in. (figure 4,4A)
6.
The safety slide switch is now reset.
7.
Install the sound absorber. (Figure 2).
8.
Install the blower cover using the four corner screws
removed earlier. (Figure 1).
HIBLOW Blower Safety Slide Switch
© Copyright 2020. All rights reserved.
Figure 1
Figure 2
Figure 3
Figure 4
Figure 2
Figure 1
17
Fig. 3A Non-Operating State
Fig. 4A Reset position