Audio Outputs
All available output signals are the same for analogue, AES and SPDIF signals so will
be described together. Analogue signals go up to 12dBu and digital signals up to
0dBFS.
Output> Analogue
Output> AES BNC
Output> AES XLR
Output> SPDIF BNC

Audio Output Menu

Tone
Int.Mic
Noise Gen.
Frame Rate>
These examples will use AES BNC.
Output> AES BNC
Steady
GLITS
EBU
Sweep
Left
Right
Access the tone menus
Output the built in mic.
Output pink or white noise
This item will only show if digital output is
selected. Set to 48kHz or 96kHz as required.
Tone Type>
Continuous tone both channels.
Graham's Line Ident Tone System. Used extensively for
Stereo line identification by the BBC amongst others.
Cyclic break on the left channel, steady on the right.
Tone rising in frequency from 20Hz to 20kHz. Press Vol- or
Vol+ to start the sweep.
Left channel only
Right channel only
6
Various types of tone output are