Armstrong 4030 설치 및 운영 지침 매뉴얼 - 페이지 9
{카테고리_이름} Armstrong 4030에 대한 설치 및 운영 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Armstrong 4030 12 페이지. Base mounted pump
Armstrong 4030에 대해서도 마찬가지입니다: 설치 및 운영 지침 매뉴얼 (12 페이지)
symptoms
Pump Fails To deliver
Pump vibrates
Seal leaks or fails
Low delivery rate
Insufficient pressure
Low bearing life
Series 4030
Base mounted pump
reasons
• Pump not primed.
• Suction line not filled.
• Air or vapour pocket in suction line.
• Inlet of Suction pipe insufficiently submerged.
• N.P.S.H. available too low.
• Suction lift too high.
• Air leaks in suction line, gland or pump joints.
• Blocked suction.
• Incorrect rotation.
• Speed too low.
• Total head of system higher than that of pump.
• Misalignment.
• Air or vapour pocket in suction line.
• Inlet of suction pipe insufficiently submerged.
• N.P.S.H. available too low. Suction lift too high.
• Blocked suction.
• Impeller damaged.
• Packing too tight.
• Misalignment of pipework.
• Operation at low capacity.
• Rotating element out of balance.
• Shaft bent.
• Poor foundations
• Misalignment.
• Impurities in water.
• Entrained air.
• Cavitation.
• Bearing failure.
• Water treatment not allowed for.
• Air or vapour pocket in suction line.
• Inlet of suction pipe insufficiently submerged.
• N.P.S.H. available too low.
• Suction lift too high.
• Air leaks in suction line, gland or pump joints.
• Blocked suction.
• Incorrect rotation.
• Speed too low.
• Excessive system friction.
• Impeller damaged
• Incorrect rotation.
• Speed too low.
• Excessive system friction.
• Impeller damaged.
• Misalignment.
• Dirt in bearings.
• Bearings too tight.
• Bearings badly installed.
• Misalignment of pipework.
• Rotating element out of balance.
• Shaft bent.
in sta l l a t io n &
o pera t ing instr uct io n s
9