DIS Sensors QG40N 사용자 설명서 - 페이지 12
{카테고리_이름} DIS Sensors QG40N에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. DIS Sensors QG40N 15 페이지. Tilt/acceleration switch (sil1 plc)
DIS Sensors QG40N에 대해서도 마찬가지입니다: 사용자 설명서 (5 페이지), 사용자 및 안전 매뉴얼 (6 페이지)
Example: Switch point = ±80°, hysteresis = 0.5°
The sensor switches from conducting(operation) to non-conducting(critical) exactly at ±80°, but
it switches from non-conducting(critical) back to conducting (operation) at ±79.5° (80° - 0.5°)
instead.
4.7.3
Delay Times
Operation to Critical delay
•
The switching output changes only when the measured angle is continuously over the switch
point ±S for more than de delay time. If it's a short vibration, the object often returns to its
safe position in the operation zone. In this case, the sensor will then not be switched to non-
conducting. The timer will be then reset to the delay time and start to monitor again.
Critical to Operation delay
•
when the sensor tilts back to the operation zone, the switching output changes only when
the measured angle is continuously below the S'(not S) for more than the delay time.
Similarly, if it's a short vibration, the sensor moves back to the critical zone immediately,
sensor will not be switched and the timer will be reset.
EMC / CE
See separate
'Declaration of Conformity'
5 Installation Guide
Mechanical drawing
DIS SENSORS BV
User Manual - QG40N Tilt/Acceleration Switch (SIL1 PLc) V2.0
Figure 6 - Hysteresis
11