Blagdon Midipond 20000 매뉴얼 - 페이지 14

{카테고리_이름} Blagdon Midipond 20000에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Blagdon Midipond 20000 16 페이지. Uv pond filter system

Blagdon Midipond 20000 매뉴얼

Green Water

Settlement test the water to ensure that there is no sediment suspended in the water. If there is
follow the brown cloudy water trouble shooting guide.
At dusk check that the UVC light is illuminated by holding a piece of paper up to the UVC outlet
and looking for the reflected pale blue UVC light. Turning the lamp on and off may aid visual
identification. (Ensure the UVC lamp is not more than 6 months old).
The UVC may be working effectively but the foams are too clean and are unable to remove the
fine coagulated waste. Treat the pond with Interpet Clear Pond and do not clean the foams until
the foam chamber starts to overflow into the carbon wool chamber.
The flow rate of the pump exceeds the maximum flow rate that the UVC is able to handle. Check
the filter specification chart and reduce the pump flow rate if needed. It is possible to purchase a
optional flow control valve that may be fitted inline between the pump and the filter to control the
flow rate.
The filter is too small for the pond, check the filter selection chart.
The UVC quartz sleeve is dirty or coated in lime scale. Gently remove the quartz sleeve and clean
in Blagdon pond pump cleaner.
Follow all cloudy water trouble shooting points.

UVC Light Not Illuminated

Check all fuses / RCD and electrical connections follow electrical installation (pages 7-8)..

Poor flow into the filter or out of the filter

Inspect and clean your pond pump, check that it is in good working order.
Check foams and filter pads ,clean as per routine maintenance if blocked.
Always use the minimum length of inlet or outlet hose needed as this will reduce back pressure
due to friction.
Ensure that the inlet hose connecter has been cut correctly to size, if not this will restrict the flow
from the pump into the filter see diagram page 5.
Ensure that the correct number of outlets are being used (see page 3).
Ensure that the inlet hose is not kinked or crushed.
Ensure that the outlet hoses are under 1m in length and that there is a drop of 15cm over this
distance, ensure that they are not kinked crushed or have a sharp bend as this will stop the filter
draining correctly.
12
17.562 Blagdon_Midipond filter instructions_20000/28000 AW.indd 15
TROUBLESHOOTING
17/07/2017 16:35