Aerial AD 630F 사용 설명서 - 페이지 10
{카테고리_이름} Aerial AD 630F에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Aerial AD 630F 18 페이지. Condensation dryer
Instruction manual condensation dryer AD 530 / AD 630 / AD 630F
The dryer does not achieve
the humidity adjusted at the
hygrostat and/or does not
switch itself off via the
hygrostat.
Attention!
The appliance must be repaired by a trained and expert personnel only. In the case of
interventions by unauthorized people, any and all warranty claims shall become null and void!
If you have any questions regarding defects and malfunctions of AERIAL-air dryers we
recommend to get in touch with your supplier.
from serie July 2003
16
The hygrostat is adjusted
onto a value below 45% r.h..
17
The unit is to small for your
application
18
There is a lot of moist in the
walls and in the floor
(Building materials) .
19
There is a defective at the
hygrostat
20
A mistake in the cooling
circuit of the dryer is
possible.
page 9
AERIAL GmbH
A condensation dryer can achieve
- depending on environmental
conditions - at a minimum a value
from 40 to 45% r.h. . Put the built-
in hygrostat on an attainable value
(e.g. approx. 50%r.h.), with it that
dehumidifier punctual may switch
off.
The air changing rates, persons in
that room and open water
surfaces decide on the humidity
load. Ask your authorized dealer
to calculate if the unit has enough
capacity for your application.
In this case, the dryer needs
some time to remove all that
water and to achieve an
acceptable humidity in that room.
Check the hygrostat. Switches the
unit off when you turn the
hygrostat to position „0"?
Check whether water gathers in
the water tank. If this is not the
case although the compressor ran
permanently, you should get in
touch with your supplier.