CAME BK 1800 설치, 운영 및 유지보수 매뉴얼 - 페이지 10
{카테고리_이름} CAME BK 1800에 대한 설치, 운영 및 유지보수 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. CAME BK 1800 18 페이지. Sliding gate operator

F63 Change COM speed
For setting the communication speed used in the CRP (Came Remote Protocol) connection system.
F65 Wireless input RIO-EDGE [T1]
RIO-EDGE wireless safety device associated to a function of choice among those available: P0= stop gate and exclude any automatic closing; to
resume movement, use the control device, P7 = reopening during closing, P8 = reclosing during opening.
For programming, see the instructions that come with the accessory.
This function only appears is the control board has been fitted with a RIO-CONN card.
F66 Wireless input RIO-EDGE [T2]
RIO-EDGE wireless safety device associated to a function of choice among those available: P0= stop gate and exclude any automatic closing; to
resume movement, use the control device, P7 = reopening during closing, P8 = reclosing during opening.
For programming, see the instructions that come with the accessory.
This function only appears is the control board has been fitted with a RIO-CONN card.
F67 Wireless input RIO-CELL [T1]
RIO-CELL is associated to any function chosen among those available: P1 = reopening during closing; P2 = reclosing during opening; P3 = partial
stop; P4 = obstruction wait.
For programming, see the instructions that come with the accessory.
This function only appears is the control board has been fitted with a RIO-CONN card.
F68 Wireless input RIO-CELL [T2]
RIO-CELL is associated to any function chosen among those available: P1 = reopening during closing; P2 = reclosing during opening; P3 = partial
stop; P4 = obstruction wait.
For programming, see the instructions that come with the accessory.
This function only appears is the control board has been fitted with a RIO-CONN card.
F71 Partial opening time
After an opening command from the button connected to 2-3P, the gate opens for an adjustable time of between five seconds and 40 seconds.
U 1 Entering a user
Entering up to 250 users and associating to each one a function of choice among those included. This must be done via transmitter or other control
device (see "ENTERING USERS WITH ASSOCIATED COMMAND paragraph).
U 2 Deleting a user
Deleting a single user
U 3 Deleting users
Deleting all users.
U4 Code decoding
For choosing the type of receiving control code: 1= all series / 2 = only
⚠ When you select a radio code, all saved transmitters will automatically be deleted.
The TWIN code lets you save multiple users with the same key, that is, key block.
A 4 Resetting parameters
Attention! The default settings will be restored.
A 5 Counting maneuvers
For viewing the number of maneuvers completed or for deleting them (001 = 100 maneuvers; 010 = 1,000 maneuvers; 100 = 10,000 maneuvers;
999 = 99,900 maneuvers; CSI = maintenance job)
H1 Version
View the firmware version.
0 = 1200 Baud / 1 = 2400 Baud / 2 = 4800 Baud / 3 = 9600 Baud / 4 = 14400 Baud / 5 = 19200
Baud / 6 = 38400 Baud (default) / 7 = 57600 Baud / 8 = 115200 Baud
OFF (default) / P0 = P0 / P7 = P7 / P8 = P8
OFF (default) / P0 = P0 / P7 = P7 / P8 = P8
OFF (default) / P1 = P1 / P2 marked areas = P2 / P3 = P3 / P4 = P4
OFF (default) / P1 = P1 / P2 marked areas = P2 / P3 = P3 / P4 = P4
5 = 5 seconds (default) /....... / 40 = 40 seconds
1 = Step-step command (open-close) / 2 = Sequential command (open-stop-close-stop) / 3 = Open
only command / 4 = Partial opening command
OFF (default) / ON = Delete all users
1 (default) / 2 / 3
Rolling Code
OFF (default) / ON
Number of maneuvers done
series / 3 = only TWIN series