F6 Maintained action
The gate opens and closes by keeping the button pressed. Opening button on contact 2-3 and closing button on contact 2-4. All other control
devices, even radio-based ones, are excluded.
F7 Command (2-7)
From the control device connected to 2-7 it performs the step-step (open-close-invert) or sequential (open-stop-close-stop) command.
F9 Obstruction detection with motor
idle
With the gate closed, opened or totally stopped, the gearmotor stays idle if the safety devices, that is, photocells or sensitive safety-edges detect
an obstruction.
F10 Gate-open signal output
It signals the gate status. The signal device is connected to contact 10-5.
F14 Sensor type selection
Setting the type of accessory for controlling the operator.
F18 Additional light
Extra light connection input on EX-W.
Outdoor light for additional visibility in the drive way.
Cycle: it stays lit from the moment the gate starts opening until it completely closes, including the automatic closing waiting time.
Courtesy: it stays on for an adjustable time of between 60 and 180 seconds. For adjusting the time, see function [F25].
F19 Automatic closing time
The automatic-closing wait starts when the opening limit switch point is reached and can be set to between 1 and 180 seconds. The automatic
closing does not activate if any of the safety devices trigger when an obstruction is detected, or after a total stop, or during a power outage.
F20 Automatic closing time after a
partial opening
The wait before the automatic closing starts after a partial opening command for an adjustable time of between 1 s and 180 s.
The automatic closing does not activate if any of the safety devices trigger when an obstruction is detected, or after a total stop, or during a power
outage.
F21 Preflashing time
Adjusting the pre-flashing time for the flashing light connected to E1-W, before each maneuver. The flashing time is adjustable from one to ten
seconds.
F25 Courtesy light time
Additional light that stays on for the required time during the when the gate is opening or closing.
EX-W contact output. It is adjustable between 60 seconds and 180 seconds.
F49 Managing serial connection
To enable the paired operating mode or the CRP (Came Remote Protocol).
F50 Save data
Saving users and saved settings in memory roll.
 This function only appears if a memory roll has been fitted into the control board.
F51 Read data
Uploading data saved in memory roll.
 This function only appears if a memory roll has been fitted into the control board.
F52 Passing parameter in paired
mode
Uploading settings from Master to Slave.
 It appears only if function [F49] is set to Paired.
F54 Opening direction
For setting the gate opening direction.
F56 Peripheral number
To set the peripheral's number from 1 to 255 for each control board when you have a system with several operators.
OFF (default) / ON
0 = Step-step (default) / 1 = Sequential
OFF (default) / ON
0
On when the barrier is open and moving (default)
=
1
during openings it flashes intermittently each half second
=
, and during closings it flashes intermittently each
second. It stays on steadily
when the barrier is open, off or when it s closed.
0 = control with transponder sensor or magnetic card reader.
1 = command with keypad selector (default).
OFF (default) / 1 = Cycle / 2 = Courtesy
OFF (default) / 1 = 1 second /... / 180 = 180 seconds
OFF / 1 = 1 second /.../ 10 = 10 seconds (default) /.../ 180 = 180 seconds
OFF (default) / 1 = 1 second /... / 10 = 10 seconds
60 = 60 seconds (default)/ 180 = 180 seconds
OFF (default) / 1 = Paired / 3 = CRP
OFF (default) / ON
OFF (default) / ON
OFF (default) / ON
OFF = Opening left (default) / ON = Opening right
1 ----> 255
/