CAME BX-246 설치 매뉴얼 - 페이지 5
{카테고리_이름} CAME BX-246에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. CAME BX-246 13 페이지. Bx series

5.5 Securing the plate and installing the assembly
The following applications are only examples, as the space for installing the ratiomotor and accessories varies according to
obstructions. It is thus up to the system installer to select the most suitable solution.
- Dig a pit to the side of the gate (see measurements from diagram).
Prepare the corrugated tubes you will need when making connections coming from the shunt pit.
N.B. the number of tubes depends on the type of system and the accessories you will hook up.
- Prepare a form box that is larger in size than the securing plate and insert it into the pit. The form box should jut 50mm above
ground level.
Insert an iron grid inside the from box to reinforce the concrete.
-Prepare the securing plate, insert the bolts into the holes and lock them using the supplied nuts and washers. Extract the preformed
brackets using a screw driver or a set of pliers.
- Position the plate on top of the grid. Careful! The tubes need to pass through the apposite holes.
Conduits for electric
cables
Shunt pit