Connection of the Gas Supply

Connect an approved gas line at the 3/8" (or ½") standard gas inlet and use an approved
sealant for this connection. Due to the high gas rate we recommend a gas supply pipe of
8mm minimum diameter. Gas pipe sizing and flueing must be in accordance with AS 5601.2

Connection Water of the Supply and Hot Water Outlet

The cold water inlet and the hot water outlet are connected via 2 standard ½" male fitting.
Use a rubber seal or other removable sealants.
Piping and components connected to the heater shall be suitable for use with potable
water. When tightening water connections to the water line, be sure to back up the fittings with
a wrench as to not damage the copper water tubing. Re-tighten the compressions nuts on the
water fittings. With the power and gas supply to the heater turned off, pressurize the water system,
purge it of all air and check for leaks.
The water heater is controlled and started by the water flow. If the water flow is higher than
2.5 l/min, the burner starts automatically and heats up the water to the desired temperature.