Balmar CFII-12/24 설치 및 운영 매뉴얼 - 페이지 4

{카테고리_이름} Balmar CFII-12/24에 대한 설치 및 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Balmar CFII-12/24 8 페이지. Dual alternator charge balancer
Balmar CFII-12/24에 대해서도 마찬가지입니다: 설치 및 운영 매뉴얼 (6 페이지)

Balmar CFII-12/24 설치 및 운영 매뉴얼
PORT REGULATOR DASH LAMP TERMINAL- Connect Terminal #6 to the port voltage regulator's dash lamp terminal
6.
via a user supplied 16-gauge wire. Female 1/4" spade terminals are supplied for connecting to Terminal #6.
7.
PORT DASH LAMP TERMINAL- Connect Terminal #7 to the port dash lamp via a user supplied 16-gauge wire. Female
1/4" spade terminals are supplied for connection to Terminal #7.
8.
PORT "DASH LAMP" LED (RED) - Indicates activation of port voltage regulator's Dash Lamp terminal. Activation of the
Dash Lamp may occur as a result of high or low voltage, high alternator or high battery temperature. If LED is illuminated, inspect
the starboard voltage regulator long display for advisory codes.
9.
GROUND TERMINAL - Connect Terminal #9 to system ground via 14-gauge BLACK wire. A female 1/4" spade terminal
is supplied for connection to Terminal #9. Termination to system ground will require a user-supplied spade or ring terminal
connector, depending on the ground location chosen. ALL GROUND CONNECTIONS MUST BE COMMON.
10.
STARBOARD "DASH LAMP" LED (GREEN)- Indicates activation of starboard voltage regulator's Dash Lamp terminal.
Activation of the Dash Lamp may occur as a result of high or low voltage, high alternator or high battery temperature. If LED is
illuminated, inspect the starboard voltage regulator long display for advisory codes.
11.
STARBOARD REGULATOR DASH LAMP TERMINAL- Connect Terminal #11 to the starboard voltage regulator's dash
lamp terminal via a user supplied 16-gauge wire. Female 1/4" spade terminals are supplied for connection to Terminal #11.
12.
STARBOARD DASH LAMP TERMINAL- Connect Terminal #12 to the starboard dash lamp via a user supplied
16-gauge wire. Female 1/4" spade terminals are supplied for connection to Terminal #12, and for connection to the starboard
regulator's dash lamp.
13.
COMMUNICATION PORT- Factory use only.
14.
COMMUNICATION PORT- Factory use only.
15.
COMMUNICATION PORT- Factory use only.
16.
STARBOARD IGNITION INPUT- Connect Terminal #16 to the starboard ignition switch or starboard engine oil pressure
switch. Terminal #16 must see zero volts when the starboard engine is turned off, and battery voltage when the starboard engine
is running. BROWN 14-Gauge user-supplied wire is recommended. A female 1/4" spade terminal is supplied for connection to
Terminal #16.
17.
STARBOARD REGULATOR IGNITION- Connect Terminal #17 to the starboard voltage regulator's BROWN ignition
wire. A BROWN ignition wire. A BROWN 14-Gauge user-supplied wire is recommended. A female 1/4" spade terminal is
supplied for connection to Terminal #17.
18.
STARBOARD "IGNITION ACTIVATED" LED (GREEN)- Indicates activation of starboard voltage regulator's ignition
wire. If LED is illuminated, but the starboard voltage regulator is inactive, check for voltage at the regulator's ignition terminal.
19.
STARBOARD ALTERNATOR FIELD OUTPUT TERMINAL (MASTER)- Connect Terminal #19 to the starboard
alternator's field input terminal via a user supplied 12-Gauge BLUE wire. A female 1/4" spade terminal is supplied for connection
to Terminal #19. Alternator-side termination will require a user-supplied spade or ring terminal connector, depending on the
alternator configuration.
20.
STARBOARD REGULATOR FIELD INPUT TERMINAL (MASTER)- Connect Terminal #20 to starboard voltage
regulator's Field Output terminal via a user-supplied 12-Gauge BLUE wire. A female 1/4" spade terminal is supplied for
connection to Terminal #20. The 12-Gauge BLUE wire will replace the regulator's 14-Gauge field wire.
"COMBINE" LED (AMBER)- Indicates activation of port and starboard alternators and voltage regulators. The CFII
21.
-12/24 will continue to supply balanced field current to both port and starboard alternators when the LED is activated.
www.balmar.net / Customer Service: +1 (360) 435-6100 x1 / Technical Support: +1 (360) 435-6100 x3
Tech Service is available Monday - Friday (8:30am - 7:30pm EST)
4