ESI ESRTD5VF 설치 지침 매뉴얼 - 페이지 7

{카테고리_이름} ESI ESRTD5VF에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. ESI ESRTD5VF 12 페이지. Digital room thermostat with tpi & delayed start
ESI ESRTD5VF에 대해서도 마찬가지입니다: 사용자 지침 (16 페이지)

ESI ESRTD5VF 설치 지침 매뉴얼

2. Installation

Installation Safety Instructions

2.1
The unit must be installed by a suitably qualified person in
accordance with the latest IEE Wiring Regulations. Isolate
mains supply before commencing installation. Please read all
instructions before proceeding.
Ensure that the fixed wiring connections to the mains supply
is via a fuse rated at not more than 3 Amps and Class 'A'
switch having a contact separation of a minimum of 3mm
in all poles. The recommended cable sizes are 1.0mm sqr or
1.5mm sqr. No earth connection is required as the product is
double insulated but ensure continuity of earth throughout
the system.

General Safety Instructions

2.2
This product complies with the essential requirements of the
following EC Directives:
• Electro-Magnetic Compatibility Directive 2014/30/EU
• Low Voltage Directive 2014/35/EU
• EC Marking Directive 2014/30/EU
Please leave the user instructions with the end user where
they should be kept in a safe place for future reference.
7