2. Installation
Installation Safety Instructions
2.1
The unit must be installed by a suitably qualified person in
accordance with the latest IEE Wiring Regulations. Isolate
mains supply before commencing installation. Please read all
instructions before proceeding.
Ensure that the fixed wiring connections to the mains supply
is via a fuse rated at not more than 3 Amps and Class 'A'
switch having a contact separation of a minimum of 3mm
in all poles. The recommended cable sizes are 1.0mm sqr or
1.5mm sqr. No earth connection is required as the product is
double insulated but ensure continuity of earth throughout
the system.
General Safety Instructions
2.2
This product complies with the essential requirements of the
following EC Directives:
• Electro-Magnetic Compatibility Directive 2014/30/EU
• Low Voltage Directive 2014/35/EU
• EC Marking Directive 2014/30/EU
Please leave the user instructions with the end user where
they should be kept in a safe place for future reference.
7