12. HOW TO USE THE HOT KEY
12.1 HOW TO PROGRAM A HOT KEY FROM THE INSTRUMENT (UPLOAD)
1.
Program one controller with the front keypad.
When the controller is ON, insert the "Hot key" and push o key; the "uPL" message
2.
appears followed a by flashing "End"
3.
Push "SET" key and the End will stop flashing.
4.
Turn OFF the instrument remove the "Hot Key", then turn it ON again.
NOTE: the "Err" message is displayed for failed programming. In this case push again o key if you
want to restart the upload again or remove the "Hot key" to abort the operation.
12.2 HOW TO PROGRAM AN INSTRUMENT USING A HOT KEY
(DOWNLOAD)
1.
Turn OFF the instrument.
2.
Insert a programmed "Hot Key" into the 5 PIN receptacle and then turn the Controller ON.
3.
Automatically the parameter list of the "Hot Key" is downloaded into the Controller memory,
the "doL" message is blinking followed a by flashing "End".
4.
After 10 seconds the instrument will restart working with the new parameters.
5.
Remove the "Hot Key"..
NOTE the message "Err" is displayed for failed programming. In this case turn the unit off and then
on if you want to restart the download again or remove the "Hot key" to abort the operation.
13. ALARM SIGNALS
Message
Cause
"P1"
Room probe failure
"P2"
Evaporator probe failure
"HA"
Maximum temperature alarm
"LA"
Minimum temperature alarm
13.1 ALARM RECOVERY
Probe alarms P1", "P2", start some seconds after the fault in the related probe; they automatically
stop some seconds after the probe restarts normal operation. Check connections before replacing
the probe. Temperature alarms "HA", "LA" automatically stop as soon as the temperature returns to
normal values.
13.2 OTHER MESSAGES
Pon
Keyboard unlocked.
PoF
Keyboard locked
noP
In programming mode: none parameter is present in Pr1
On the display or in dP2, dP3, dP4: the selected probe is nor enabled
14. TECHNICAL DATA
Housing: self extinguishing ABS.
Case: facia 38x185 mm; depth 76mm
Mounting : panel mounting in a 150x31 mm panel cut-out with two screws.
Distance between the holes 165mm
Protection: IP20; Frontal protection: IP65 with frontal gasket mod RG-L. (optional)
Connections: Screw terminal block
2,5 mm
≤
Power supply: 230Vac or. 110Vac or 24Vac
Power absorption: 5VA max.
Display: 3 digits, 14,2 mm high; Inputs: 2 NTC probes.
Relay outputs: Total current on loads MAX. 20A
compressor: relay SPST 16(3)A, 250Vac
light: relay SPST 8 or 16(3) A, 250Vac
defrost: relay SPST 16(3) A, 250Vac
Other output : buzzer (optional)
Serial output : TTL standard; Communication protocol: Modbus - RTU
Data storing: on the non-volatile memory (EEPROM).
Kind of action: 1B; Pollution grade: 2;Software class: A.;
Rated impulsive voltage: 2500V; Over voltage Category: II
Operating temperature: 0÷60 °C; Storage temperature: -30÷85 °C.
Relative humidity: 20÷85% (no condensing)
Measuring and regulation range: NTC probe: -40÷110°C (-40÷230°F);
Resolution: 0,1 °C or 1°C or 1 °F (selectable); Accuracy (ambient temp. 25°C): ±0,7 °C ±1 digit
15. CONNECTIONS
Supply: 120Vac or 24Vac: connect to terminals 7-8
1598029050 XW40L NFR GB r1.0 11.07.2008.doc
Outputs
Compressor output acc. to par. "Con" and "COF"
Defrost end is timed
Outputs unchanged.
Outputs unchanged.
3 x 2mm.
∅
2
heat-resistant wiring and 6,3mm Faston
10%
±
16. DEFAULT SETTING VALUES
Label
Name
Set Set point
Hy Differential
LS Minimum set point
US Maximum set point
Ot Thermostat probe calibration
P2P Evaporator probe presence
OE Evaporator probe calibration
OdS Outputs delay at start up
AC Anti-short cycle delay
CCt Continuous cycle duration
CCS Set point for continuous cycle
COn Compressor ON time with faulty probe
COF Compressor OFF time with faulty probe 0 ÷ 255 min
CF Temperature measurement unit
rES Resolution
tdF Defrost type
dtE Defrost termination temperature
IdF Interval between defrost cycles
MdF (Maximum) length for defrost
dFd Displaying during defrost
dAd MAX display delay after defrost
Fdt Draining time
dPo First defrost after start-up
dAF Defrost delay after fast freezing
ALc Temperat. alarms configuration
ALU MAXIMUM temperature alarm
ALL Minimum temperature alarm
ALd Temperature alarm delay
dAO Delay of temperature alarm at start up
Adr Serial address
rEL Software release
Ptb Map code
Dixell S.p.A. Z.I. Via dell'Industria, 27
32010 Pieve d'Alpago (BL) ITALY
tel. +39 - 0437 - 98 33 - fax +39 - 0437 - 98 93 13
E-mail: [email protected] - http://www.dixell.com
XW40L
1598029050
Range
Value Level
LS÷US
0
0,1÷25.5°C/ 1÷ 255°F
4
-50°C÷SET/-58°F÷SET
-2
SET÷110°C/ SET ÷ 230°F
16
-12÷12°C /-120÷120°F
0
n=not present; Y=pres.
Y
-12÷12°C /-120÷120°F
0
0÷255 min
1
0 ÷ 50 min
1
0.0÷24.0h
0.0
(-55.0÷150,0°C) (-67÷302°F)
0
0 ÷ 255 min
15
20
°C ÷ °F
°C
in=integer; dE= dec.point
in
EL=el. heater; in= hot gas
EL
-50 ÷ 50 °C
8.0
1 ÷ 120 ore
4
0 ÷ 255 min
60
rt, it, SEt, DEF
it
0 ÷ 255 min
30
0÷120 min
0
n=after IdF; y=immed.
n
0 ÷ 23h e 50'
0.0
rE= related to set;
rE
Ab = absolute
10
Set÷110.0°C; Set÷230°F
-50.0°C÷Set/ -58°F÷Set
10
0 ÷ 255 min
10
0 ÷ 23h e 50'
2.0
1÷247
1
--
1.8
--
---
Pr1
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr1
Pr2
Pr2
Pr1
Pr1
Pr1
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
3/3