To request the account balance of the SIM card (by number from the BAL
setting) use SMS command «USSD». If you need to request data for another
phone number, add it in the command: «USSD:*XXX#».
Additional commands
Send USSD-request *XXX# using the module's SIM card
Send text message ХХХ from SIM card's number to NNN SMS:NNN:XXX
Request GSM stations data (MCC,MNC,LAC,CID)
Note: MCC, MNC, LAC and CID data allow to determine the location of the
vehicle on the map (using Google, Yandex services, etc.).
LAC and CID fields values are displayed in hexadecimal notation.
Heater's Diagnostics
Read heater's errors
Erase heater's errors
Note: diagnostics is only possible for digital heaters.
Settings
You can enter several settings simultaneously, dividing them by commas.
If the password is set (PASS:XXXX), then before entering any instruction,
you should include its value with no spaces (XXXXSETTINGS1).
General Settings Commands
Request a text message (SMS) with general settings
Request a text message (SMS) with Internet settings
Restore to factory default settings
1) On the first launch the module automatically detects the type of the
digital heater. For the forced change of the connected heater's type use
text message instruction HEATER-XX, where XX:
A0 – Automatic determination of the heater's type (digital/analog);
А1 - Analog heater;
W2 – Thermo Top V/VEVO;
W4 – Timer 1533 Emulation;
W6 – Telestart (ver.2) Emulation;
2) To change the default operation time of the heater use text message
command TIME1:XX, where XX is operation time from 10 to 120 minutes.
3) If output OUT controls ventilation of the car's interior set up the
delay time for switching on output OUT using setting TIME2:XX and/or set
up switching of output OUT based on the coolant temperature using setting
LTEMP1:XX, where value ХХ can be from 0 to 99°С (0 - the setting is OFF).
4) LTEMP2:XX setting allows switching the heater off based on the
coolant temperature before the operation time TIME1:XX.
Attention! LTEMP1/2 are available not for all heater models.
Command
USSD:*XXX#
GSMINFO
Command
READ
ERASE
Command
SETTINGS1
SETTINGS2
SETDEFAULT
W1 – Thermo Top C/Z/V/EVO/VEVO;
W3 – WTT Emulation;
W5 – Telestart (ver.1) Emulation;
W7 – Ventilation (summer mode).
Technical Settings
Type of connected heater (see the description above)
Shut off heater when there are errors on digital bus
Binding to other control modules
Default operating time of heater, 10–120 min
Delay before switching on of OUT, 1–20 min
Delay before switching off of OUT, 1–9 min
Switch off OUT by coolant temp, 0-OFF (0-99°С)
Switch off heater by coolant temp, 0-OFF (0-99°С)
Type of button: latching / non-latching
Switching on of OUT when the digital bus is activated
Manual control of OUT (on/off)
Restoring of the state for OUT after power supply
1) By default, the module uses the option of forwarding all incoming
SMS that are not commands to the last phone number registered in the
module or entered into cells NUM1/2/3.
To deactivate this option use commands SMSF0.
2) Automatic SMS notifications (1-ON, 0-OFF):
SMSW1 - transmitting SMS status when the heater's status changes;
SMSE1 - notifications about heater's operation errors.
3) CALL0 setting switches the module into the mode of dropping
incoming calls which allows saving money.
4) NUM1/2/3 commands set up authorized phone numbers. Phone
numbers should be entered in the international format.
5) BTIMER1:N allows receiving an automated SMS with account balance
information every N days. To switch off this option send a SMS command
with value 0 («BTIMER1:0»).
User Settings
Forwarding of incoming SMS (to switch off use SMSF0)
SMS status when the heater's status changes
SMS about control bus errors
CALL1 - response incoming call, CALL0 - dropping call
Setting the password before entering SMS-commands
Save the phone number into cell NUM1
Save the phone number into cell NUM2
Save the phone number into cell NUM3
Save USSD number for account balance requests
Timer for sending SMS with balance, 0-99 days (0-OFF) BTIMER1:10
Timer for sending balance into application, 1-9 hours
Transliteration of cyrillic characters
Command
HEATER-XX
RSTOP1 /0
BIND1 /0
TIME1:30
TIME2:0
TIME3:0
LTEMP1:0
LTEMP2:0
FIXKEY1 /0
SEPARLINE1 /0
SEPAROUT1 /0
KEEPOUT1 /0
Command
SMSF1 /0
SMSW1 /0
SMSE1 /0
CALL1 /0
PASS:XXXX
NUM1:+YYYYYYY
NUM2:+YYYYYYY
NUM3:+YYYYYYY
BAL:*XXX#
BTIMER2:5
TRANSLIT1 /0