6200X and 6500X Tall Drop Elbows
This elbow is designed for use with standard 4" top seal service
station adapters. To properly operate and maintain your Dixon Bayco
6200X series elbow the following instructions are provided. Please
read with care as improper handling or maintenance may cause a
hazardous condition.
Do not modify your Dixon Bayco 6200X / 6500X series
elbow for any reason. It can result in a hazardous condition due
to operating difficulties or operation malfunction. Disassembly
or tampering will void the product warranty.
Never smoke or allow an open flame near your dispenser when
handling volatile materials such as gasoline and fuels. An explosion
could result. Remember safety is everyone's business.

Installation

1. When the Dixon Bayco 6200X / 6500X elbow is shipped, the sight
glass and gaskets are attached in a plastic bag attached to the
elbow. These must be installed with the required mating Bayco inlet
(3" or 4" male or female purchased separately).
2. Take the sight glass and gaskets out of the plastic bag and place
one gasket inside the elbow inlet end and make sure it is sealed
evenly.
3. Carefully (keep straight) slide the sight glass into the inlet end and
onto the installed gasket.
4. Place the other gasket inside the inlet and on the sight glass.
5. Attach the mating inlet using the four socket head cap screws
supplied.
6. Coat the cap screws with anti-seize compound.
Lubricate Stem
This product has been assembled with anti-seize compound and
lubricated for easy maintenance and trouble-free service. However,
we recommend lubricating the stem through the grease nipple using
lithium based or quality automotive type grease prior to service. It is
recommended to apply lubricant to grease nipple, cam arm bearings,
and other moving parts every month. Monthly inspection and
lubrication become mandatory for items that are seldom used.
Condensation, rain and road salts can cause corrosion build-up and
binding when product not in use.
6200X & 6500X
090086 R6