6200X and 6500X Tall Drop Elbows

Check Operation

1. Place elbow bottom end on service station adapter (elbow is
designed for use with 4" top seal adapter only).
2. Move operators handle to 11 o'clock the open/unclamped position.
3. Release and hold the safety latch if equipped with one. Move the
handle clockwise to 2 o'clock position for full clamping (lever cannot
be moved any farther).
3. Check locking arms on adapter. If the elbow is fitted with a safety
latch, make sure the stem pin is in the latch notch, preventing
movement of operating handle.
4. Release by moving handle to 11 o'clock. If fitted with safety latch,
lift the latch lever and operating lever at the same time.

Care and Handling

Dixon Bayco drop elbows are tested at the factory and are in proper
working condition when shipped. Drop elbows are designed to be
tough and to provide long service with reasonable care and handling.
To ensure long service, Dixon Bayco elbows should not be thrown,
dropped or dragged; such actions may compromise the integrity and
reduce the service life of the product.
Inspection
Drop elbows can fail to operate if not properly maintained. If the
6200X / 6500X elbow develops any problems, remove from service
and contact your Dixon Bayco distributor describing the difficulty. The
distributor will provide further instructions repair and warranty of the
product.
Elbows should be inspected monthly. Check the main gasket seal,
the sight glass, and the flange where the base is attached to the
elbow body for any signs of leakage. Change seals if necessary.
Check the sight glass for cracks or damage and replace if needed.
Check and tighten all fasteners periodically. Lubricate the lever stem.
Check the bushings and replace if cracked or worn, and change if
required. Check operation as per above.
4
090086 R6
6200X & 6500X