Altrad BELLE WPX 3/30 운영자 매뉴얼 - 페이지 9

{카테고리_이름} Altrad BELLE WPX 3/30에 대한 운영자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Altrad BELLE WPX 3/30 18 페이지.
Altrad BELLE WPX 3/30에 대해서도 마찬가지입니다: 운영자 매뉴얼 (19 페이지)

Altrad BELLE WPX 3/30 운영자 매뉴얼
CAUTION
Before connecting the hose to the Water Pump you must lay the hose out to its full length.
SUCTION HOSE INSTALLATION
Use a commercially available hose and hose connector with the hose clamp provided with the pump. The suction hose must be
reinforced with a non-collapsible wall or braided wire construction.
DO NOT use a hose smaller than the Water Pump's suction port size. Minimum hose size = 3in (80 mm)
The suction hose should be no longer than necessary. Water Pump performance is best when the pump is near the water level, and
the hoses are short.
Use a hose clamp to securely fasten the hose connector to the suction hose in order to prevent air leakage and loss of suction. Verify
that the hose connector sealing washer is in good condition.
Install the strainer (provided with the Water Pump) on the other end of the suction hose, and secure it with a hose clamp. The strainer
will help to prevent the pump from becoming clogged or damaged by debris.
Securely tighten the hose connector on the pump suction port.
1.
Suction Port.
2.
Sealing Washer.
3.
Hose Coupler.
4.
Hose Clamp Ring.
5.
Hose Clamp.
6.
Suction Hose.
7.
Strainer

Hose Connection

DO NOT connect either of the hoses to the Water Pump whilst the engine is running. This will cause
extensive damage.
Hose Connector
(Commercially
Available)
1
2
3
Hose Connector
(Commercially
Available)
6
6
9
4
5
6
5
7
GB