● HOW TO REMOVE AIR FROM THE WATERWAY:
It is necessary to perform the air drawing step for the following situations:
○ Initial use
○ Error indication E – 2
○ Air was mixed in to electrolysis agent supply tube
○ Electrolysis agent tank went to empty and new agent supplied
Air drawing of pump.
Turn the diverter lever horizontal and then turn the water on.
1)
Power on and check the display panel indicating processing value.
2)
Open the operation panel and press air draw button.
3)
* Air drawing lamp will come on and the air drawing operation will start.
* Air drawing operation takes around 6 minutes to complete.
* If the process is interrupted, press the air draw button again.
* No operational button will work during the air drawing process.
Air drawing operation will stop
4)
automatically after the air drawing
process is finished.
* Water will run out from outlet
position for a maximum of 40
seconds before the drain
operation finishes.
* Water will stop after the air drawing
operation and the air draw lamp
will shut off..
* While air drawing, the outlet water
should not be used for any
purpose.
* If the E-2 indicator comes on, an
empty electrolysis agent liquid
condition may exist and terminating the
air drawing process.
When the error condition E2 is indicated, please follow the steps below:
①
②
Is there an adequate amount of Electrolysis agent?
Check the tube connection between electrolysis agent tank and the
12