As shown on the picture below, remove the plug of the drainage cap, the aqueduct
and place the other end of the aqueduct into the water container or drain
channel.
•
When entering dehumidification mode, if the room temperature ≥17 ºC (62 ºF),
the compressor will start to work. When the room temperature
≤15 ºC (59 ºF), the compressor stops. When the temperatures raises back to
≥17 ºC, the compressor restarts again.
(in order to protect the compressor, it will be restarted 3min. later).
•
In dehumidification mode, the speed of the fan is by default at Low speed and
the wind speed is not adjustable.
•
Temperature cannot be set.
Note: when using the dehumidify function, you should remove the exit pipe
components, or else this function will fail to perform and the error message of "FL"
will appear indicating that the water level is full.
Timer mode
•
In standby mode, press the timer button to set ON time. Press the Up and Down
buttons to set the starting time (1~24H), the timer indicator lamp lights on.
•
In Startup mode, press the timer button to set OFF time. Press the Up and Down
buttons to set the switch off time (1~24H), the timer indicator lamp lights on.
Important Note:
•
Never turn off the air conditioner by unplugging it from the power supply. Always press the
"ON / OFF" button and wait a few minutes before unplugging it. This allows the device to perform
a check cycle to verify operation.
Water Drainage
The product has an automatic water evaporation system. The circulation of condensed water, cools
down the condenser. This not only increases refrigeration efficiency but also saves energy.
•
When the water tank is full, the LCD display indicates "FL" and
the compressor stops working automatically. At this point:
1. Turn the unit off and unplug the power cord.
2. Remove the exhaust duct assembly.
3. Move the unit to an appropriate place.
4. Unscrew the water drainage cover and unplug the water blocker.
Use a water container to remove the water from under the unit.
5. Plug in the water drainage cover well.
6. Reinstall the exhaust duct assembly and start the machine.