Alula RE614-Au 빠른 시작 매뉴얼 - 페이지 8

{카테고리_이름} Alula RE614-Au에 대한 빠른 시작 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Alula RE614-Au 13 페이지. Smoke alarm connect+ encrypted

Figure 7c
Figure 7d
SELF TAPPING
Attach the Alarm to the mounting plate.
Line up the screw (not supplied) on the "U"
shaped recessed area shown in Figure 7c and
screw firmly home.
To remove the Alarm from the ceiling,
remove the screw first, and then twist off
anti-clockwise.
7. Testing, Maintenance and

Power Supply Monitoring

Your Alarm is a life saving device and should be
checked periodically.
7.1 Manually Testing your Alarms
It is recommended that you test your Alarms
after installation and then at least weekly to
ensure the units are working. It will also help
you and your family to become familiar with
the sound of the Alarms.
- Press and hold the Test Button until the
Alarm sounds and the red light flashes (see
Figure 7). The Alarm will stop sounding shortly
after the button is released.
- Repeat this procedure for all other Alarms in
the system.
WARNING: Do not test with flame.
This can set fire to the Alarm and damage the
house. We do not recommend testing with
smoke as the results can be misleading unless
special apparatus is used.
When you press the Test button it simulates
the effect of smoke in a Smoke Alarm which it
could experience in a real fire.
7.2 Test/Silence Button to Control Nuisance
Alarms
The Smoke Alarms have a combined Test/
Silence button to help you control nuisance/
TAMPERPROOF SCREW
SCREW
2 to 3 mm
false alarms.
If, when the Alarm sounds, there is no sign of
smoke or noise to indicate that there is a fire,
it should be assumed that it is due to an actual
fire and the dwelling should be evacuated
immediately.
Check the house carefully in case there is a
small fire smouldering somewhere.
Check whether there is some source of smoke
or fumes, for example cooking fumes being
drawn past the Alarm by an extractor.
If there are frequent nuisance/false alarms
it may be necessary to re-locate the Smoke
Alarm away from the source of the fumes.
1. To cancel a false alarm from a Smoke Alarm
(which has its red light flashing rapidly), press
the Test/Silence button (the Smoke Alarm will
automatically switch to a reduced sensitivity
condition).
The Smoke Alarms will be silenced for a period
of approximately 10 minutes. The red light on
the cover of the Smoke Alarm will flash every
8 seconds to indicate that the unit has been
silenced.
2. The Smoke Alarm will reset to normal
sensitivity at the end of the silenced period
(10 minutes). If additional silenced time is
required, simply push the Test/Silence button
again.
3. If kitchen usage/layout is such that there
are an unacceptable level of nuisance alarms,
re-locate the Smoke Alarm further away where
it will be less affected by cooking fumes etc.
We recommend the use of a Heat Alarm in the
Kitchen area to avoid such nuisance alarms.
7.3 Power Supply Monitoring
7.3.1 What to do when an Alarm is beeping:
A Smoke Alarm is beeping about every 48
seconds with the yellow light flashing at the
same time:
- The battery contained in the smoke alarm is
low. Replace the entire smoke alarm.
Dispose of used smoke alarm promptly. Keep
away from children. Do not disassemble and
do not dispose of in fire
7.4 Cleaning your Alarm
Clean your Alarm regularly. Use a soft bristle
brush or the brush attachment of your vacuum
cleaner to remove dust and cobwebs from the
side slots where the smoke enters. To clean
the cover, wipe with a damp cloth and dry
thoroughly.
WARNING: Do not paint your Alarm.
Other than the maintenance and cleaning
described in this leaflet, no other customer
servicing of this product is required. Repairs,
8