Alula RE605 빠른 시작 매뉴얼

{카테고리_이름} Alula RE605에 대한 빠른 시작 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Alula RE605 2 페이지. Temperature sensor connect+ compatible
Alula RE605에 대해서도 마찬가지입니다: 빠른 시작 매뉴얼 (2 페이지)

Alula RE605 빠른 시작 매뉴얼
The RE605 Temperature Sensor
freeze and overheat conditions. The sensor will alarm
when the temperature trip points are reached.
Features
• Indicates freeze and overheat warnings
• Industry-leading wireless range and battery life
• Secure encrypted wireless transmissions
• 5-year warranty
Enroll
by placing the panel into wireless enrollment
mode, and then removing the cover to send an
enrollment signal. Alternatively, the sensor can be
enrolled by scanning its bar code using the Connect+
Installer App or by entering its 8-character serial
number on the interactive service provider's web portal.
The overheat input must be enabled as an additional
zone using the installer app or the interactive service
provider's web portal.
Options for sending an Enrollment Signal
• Remove the battery tab and cover to trip
tamper
.
Install
by mounting the sensor in the desired location
using two #4 or #6 screws. An optional cover-securing
screw is included. Alternatively, the sensor can also be
installed using 3M™ VHB™ tape.
Freeze or Heat alarms
temperature trip points are reached.
Temperature Trip Points
• Heat alarms when over 100°F (38°C)
• Heat restores when under 97°F (36°C)
• Freeze alarms when under 45°F (7°C)
• Freeze restores when over 48°F (9°C)
Pro Tips
3M™ VHB™ Tape works great if the surface is prop-
erly prepared and firm pressure is applied for over 10
seconds.
Surface Preparation
• Clean the surface
• Ensure the mounting surface temperature is above 50°F
Use the panel installation guide to verify proper system setup.
RE605 Temperature Sensor
Connect+
is used to detect
are transmitted when the
Encrypted
Mounting Screw Holes
Cover-Securing Screw Hole
I