PROGRAMMING MANUAL FOR AM45 MOTORS ER-P SERIES
1. TECHNICAL SPECIFICATIONS
Power supply:
Power consumption:
Limit swiches:
Operating temperature:
Protection degree:
Frequency:
Average range:
Reacts on the obstacles.
Works with all AC series transmitters included in the ALUPROF S.A. offer.
Ability of programming up to 20 transmitters. Each next transmitter will overwrite the last programmed one.
Company reserves the tolerance of catalog data due the different conditions usage.
2. ELECTRICAL CONNECTIONS
- Installation of the motor should be carried out by authorized persons.
- The motor is designed for use in dry rooms and should not be exposed
to direct weather conditions.
- The motor should be powered by a separate circuit and protected by a
quick fuse for example: circuit breaker type B10
We reserve the right to any technical change.
Valid on 2022.01.27
PROGRAMMING MANUAL FOR AM45 MOTORS ER-P SERIES
230 VAC / 50 Hz
135 W, 170 W, 200 W
Electronic
~ -10°C - ~ +60°C
IP44
433.92 MHz
80 meters (in open space), 20 meters (inside buildings)
230V / 50Hz
NOTE
For the obstacle response system to work properly:
- security springs WB or WL&P, W OCTOEASY must be used,
- side locks or stoppers in the endslat must be used,,
- adjust the maxiumum torque of the motor (Nm) to the weight of the
curtain,,
- upper and lower limit position sholud be set up
1