Aluprof AL-BR01 설치, 조립 및 운영 매뉴얼 - 페이지 2
{카테고리_이름} Aluprof AL-BR01에 대한 설치, 조립 및 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Aluprof AL-BR01 4 페이지. Gate control unit
3. Technical specifications.
- Power supply: ~230V/50Hz
- power consumption: 0,4 W
- fuse: 250VAC / 4A
- works with motors up to 230 Nm
- Frequency: 433.92 Mhz
- up to 12 transmitters can be programmed
- Operating temperature: ~ -20
- Average range: 200 meters (in open space)
35 meters (inside buildings)
- Dimensions: 150x100x70 mm
Company reserves the tolerance of catalog data due the different conditions usage.
Works with S, BD and M versions of tubular motors and can match all DC remote controllers..
4. layout of the elements
4.1. Wiring diagram.
input / output AC
1, 2. protective wire
3.
230V AC supply – L wire (phase)
4.
230V AC supply – N wire (neutral)
5.
Lighting supply – N wire (neutral)
6.
Lighting supply – L wire (phase)
7.
Drive supply – N wire (joint)
8.
Drive supply – L1 wire (UP direction)
9.
Drive supply – L2 wire (DOWN direction)
2
°
C ~ +55
°
C
T1
- power transformer
F1
- fuse: 250VAC / 4A
K1, K2, K3 - relays
P1
- potentiometer (lighting operation time)
P2
- potentiometer (drive operation time)
1-9
- input / output AC
10 - 17
- input / output DC
SW1 - DIP 1 - photocell connection
SW2 - DIP 2 - optical bar connection
PROG
- programming button
T1, T2
- photocell jumper
input / output DC
10, 11. Photocell supply 12V DC)
12.
Photocell input (NC)
13, 14. External button (monostable)
15, 17. Optical bar supply (12V DC)
16.
Optical bar input.
We reserve the right to any technical change.
Valid on 2019.11.18