Aluprof AL-BR01 Manual de instalação, montagem e funcionamento - Página 2

Procurar online ou descarregar pdf Manual de instalação, montagem e funcionamento para Unidade de controlo Aluprof AL-BR01. Aluprof AL-BR01 4 páginas. Gate control unit

3. Technical specifications.
- Power supply: ~230V/50Hz
- power consumption: 0,4 W
- fuse: 250VAC / 4A
- works with motors up to 230 Nm
- Frequency: 433.92 Mhz
- up to 12 transmitters can be programmed
- Operating temperature: ~ -20
- Average range: 200 meters (in open space)
35 meters (inside buildings)
- Dimensions: 150x100x70 mm
Company reserves the tolerance of catalog data due the different conditions usage.
Works with S, BD and M versions of tubular motors and can match all DC remote controllers..
4. layout of the elements
4.1. Wiring diagram.
input / output AC
1, 2. protective wire
3.
230V AC supply – L wire (phase)
4.
230V AC supply – N wire (neutral)
5.
Lighting supply – N wire (neutral)
6.
Lighting supply – L wire (phase)
7.
Drive supply – N wire (joint)
8.
Drive supply – L1 wire (UP direction)
9.
Drive supply – L2 wire (DOWN direction)
2
°
C ~ +55
°
C
T1
- power transformer
F1
- fuse: 250VAC / 4A
K1, K2, K3 - relays
P1
- potentiometer (lighting operation time)
P2
- potentiometer (drive operation time)
1-9
- input / output AC
10 - 17
- input / output DC
SW1 - DIP 1 - photocell connection
SW2 - DIP 2 - optical bar connection
PROG
- programming button
T1, T2
- photocell jumper
input / output DC
10, 11. Photocell supply 12V DC)
12.
Photocell input (NC)
13, 14. External button (monostable)
15, 17. Optical bar supply (12V DC)
16.
Optical bar input.
We reserve the right to any technical change.
Valid on 2019.11.18