ALUZ A8 Series 매뉴얼 - 페이지 13

{카테고리_이름} ALUZ A8 Series에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. ALUZ A8 Series 14 페이지. Tape
ALUZ A8 Series에 대해서도 마찬가지입니다: 매뉴얼 (12 페이지), 매뉴얼 (2 페이지), 설치 매뉴얼 (13 페이지)

ALUZ A8 Series 매뉴얼

CONTINUITY TEST

A continuity test is performed to determine if electricity can pass
through two points on an electrical circuit. This helps identify shorts or
malfunctions in the line or luminaire. Use a multimeter or continuity
tester to perform the steps below.
• Always perform a continuity test before connecting to power source.
• Malfunctions are not always as obvious as the lights not turning on.
• A short or malfunction in the line or luminaire will cause damage over
time, irreparably damaging the lighting and voiding warranty.
EXAMPLE OF MULTIMETER (BY OTHERS)
V
AC
1
Turn off power before beginning. Verify power is off by using a non-
contact circuit tester (by others). Touch the probe of the tester to
the positive wire of the power source. The tester will light up if an
electrical current is detected.
2
Setup your multimeter tester (by others). First, insert the black
probe lead into the COM jack, then insert the red probe lead into
the VΩ jack.
3
Verify multimeter is functional by touching probes together.
The multimeter should beep, flash, or read 0Ω (ohms) of resistance.
4
Touch the red probe to the black wire and the black probe to each
colored wire. If a conductive path is formed between the black wire
and any other wire, the multimeter will beep, flash, or read 0Ω
(ohms). Troubleshoot to identify the malfunction in the line. If there
is no conductive path, the multimeter will not show any feedback.
1170 N Red Gum St, Anaheim, CA 92806
aluz.lighting
© ALUZ All Rights Reserved. ALUZ reserves the right to make changes or withdraw specifi cations without prior notice.
A8 Series | LED Tape
ZIZA Tape
(A8-ZIZA-TAPE)
2
1
( +)
24
866.ALUZ.LTG | 714.535.7900
5
Touch the red probe to the fi xture extrusion and the black probe to
the black wire. If a conductive path is formed between the extrusion
and the black wire, the multimeter will beep, flash, or read 0Ω
(ohms). Troubleshoot to identify the malfunction in the line. If there
is no conductive path, the multimeter will not show any feedback.
6
Touch the red probe to the fi xture extrusion and the black probe to
the each colored wire. If a conductive path is formed between the
extrusion and any colored wire, the multimeter will beep, flash, or
read 0Ω (ohms). Troubleshoot to identify the malfunction in the
line. If there is no conductive path, the multimeter will not show
any feedback.
7
Set multimeter to DC voltage and test power source. Confi rm the
correct voltage before connecting luminaire to power source. If the
voltage reading is more than 1 volt greater than the marked output
voltage, there is a problem with the power source or driver.
8
Connect luminaire to power source via power connector. If LEDs
do not turn on, there is an issue with the wiring. Troubleshoot to
identify the problem.
Page 13 of 13
Continuity Test
( +)
24
24
Installation Instructions
8 / 11 / 2023 / Rev 2