PUMP SAVER
CARE AND MAINTENANCE
Turn unit off and disconnect the gun before adding
pump protector. Unscrew threaded top from bottle to
remove seal and reattach threaded top to bottle.
Remove black cap from bottle.
1) Place top of pump saver bottle onto the garden
hose adapter.
2) Secure pump saver bottle by turning in a clockwise
direction.
3) Turn the power on.
4) Squeeze bottle to help it into the pump.
TROUBLESHOOTING
If you have any questions regarding the product, please call customer service at 1-866-235-5112.
PROBLEM
Unit will not turn on.
The high pressure (HP)
hose will not connect/
stay connected to the
spray gun. Is this a
spray gun problem?
The unit is running but
there is no water flow.
14
95028_IM_ARBC_AR1850_EN_REV00_20181224.indd 14
CORRECTIVE ACTION
1. The GFCI module on the end of the power cord must be plugged directly into an outlet.
2. Do not use an extension cord.
3. With the GFCI Connected make sure the power switch is turned on.
Note: When power switch is turned on, the power washer will turn on by itself for 1-2
seconds and shut off. This is normal.
1. In most cases, the spray gun is not the problem. The problem is the rubber sleeve
covering the fitting at the end of the high pressure hose. It has likely slipped up toward
the metal tip. To fix: wiggle, twist and/or pull the rubber sleeve down until the entire tip
is visible plus an 1/8 in. of the metal fitting below the tip. Now try to insert the hose tip
into the spray gun. It should "click" into place and will not come out until the hose is
released by pushing in the lever on the underside of the gun. You may cut away the end
of the sleeve with a sharp knife if unable to move the sleeve down. Be careful not to cut
or puncture the hose.
2. Do not push in the release button when connecting the high pressure hose.
1. Power should NOT be turned on until water comes through the spray gun. Doing so will
damage the motor.
2. Check the water source.
3. Eject the nozzle from the lance to determine if clog is coming from the nozzle (If nozzle
is clogged, see nozzle cleaning instructions under "Cleaning nozzles").
4. Take off the lance and just spray out of the spray gun. This will indicate if the problem is
with the lance.
5. Check Garden Hose Adapter for loose connection and the filter for debris.
5) Turn power off when pump saver exits the machine's
water outlet.
Note: Instructions on Pump Saver Bottle are generic and
not model specific.