ASG ASG-D35 운영 매뉴얼 - 페이지 3
{카테고리_이름} ASG ASG-D35에 대한 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. ASG ASG-D35 10 페이지. Mini digital torque wrenches and screwdrivers
ASG Mini Digital Torque Wrenches and Screwdrivers
Operation Manual
Installing the Battery
Remove the battery cap by turning counter clockwise using a coin. Insert one AAA
battery matching the +/- polarity of the battery to the battery compartment.
To install the battery cap, with the display facing up, start with the small mark on the
battery cap at the 6 o'clock position then turn clockwise to approximately the 8 o'clock
position. If a known good battery is installed with the proper polarity and the tool does
not operate remove and rotate the cap 180o and reinstall.
CAUTION: Do not over tighten the cap. If the cap is installed in
the correct position, and the tool still does not work, check to
make sure the metal contact and spring are in place in the cap.
The part number for a replacement cap is #728084.
ASG, Division of Jergens, Inc.
S. Waterloo Road | Cleveland, OH
15700
44110-3898
| Phone: (
| Fax: (
| Email: [email protected] | Web: www.asg-jergens.com | Revision: 11/14/2019 | Page 3 of 10
888) 486-6163
216) 481-4519
Display and Button Functions
All programming is done with the buttons on the face of the tool.
1. Button #1 is the CLEAR /RESET button. Press "C" to turn the tool on or reset
the torque in peak mode. The tool will auto shut off after several minutes of
inactivity.*
2. Button #2 is the UNIT/SET button. Press "U/S" to change the engineering units,
enter program mode or advance while in program mode.
3. Button #3 is the MEMORY button. Press the "M" button to select memory preset
or store the reading in peak mode.
4. Buttons #4 are the UP/DOWN buttons. Press the UP/DOWN buttons to increase or
decrease the torque reading seen on the display, or to select a program option.
•
The GREEN LED will light up when the applied torque reaches 90% of the
TARGET TORQUE. The BUZZER will also beep intermittently. When the applied
torque reaches 99.5% of the target torque, the GREEN LED will remain lit and the
BUZZER change to a steady tone.
•
The RED LED will light up when the applied torque reaches 99.5% of the target
torque.
•
* When [SEnd ] is seen on the display auto shut off is canceled.
4
2
3
1
4