ASGCO CHEVRON 설치, 운영 및 유지보수 지침 매뉴얼 - 페이지 12

{카테고리_이름} ASGCO CHEVRON에 대한 설치, 운영 및 유지보수 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. ASGCO CHEVRON 12 페이지. Belt cleaners

Maintenance

ASGCO Mfg., Inc.
The second shaft is installed with all of the discs bending in the opposite
direction. Continue to alternate the direction of the discs in each
subsequent shaft installation.
Head
Pulley
Move on to the next Chevron shaft installation, using this same step-by-
step procedure. Remember that the direction of the discs must be
alternated on each subsequent installation.
• When used in a 24-hour operation, the Chevron must be adjusted every
four months. Grease hoses should be installed if the Chevron mounting
location prevents easy lubrication.
• Grease the bearing periodically.
• Operation of the conveyor belt without material should be kept to a
minimum.