All setup functions except the Stow and Deploy Positions can be scrolled through by pressing the Stream switch. Each
time the Stream switch is pressed, another function is active for configuration. If a function is configured and saved
using the Fog switch, the next function will be automatically selected. Activating the Stream command will abort this
function without storing the position and the next function will be selected. Entering the Stow and Deploy Positions
programming modes can only be accomplished by activating the Stow or Deploy switch while at the start of the setup
menu (LED Code 1 Slow blink). (See the sections for Stow Position and Deploy Position for more detail).
To aid in determining which setup menu the monitor is in, the LED on the operator station has been programmed to blink
a different code for each function. Table 3-1 below lists the LED codes for each function. The codes have two parts.
The LED code will start with either one, two, three or four short blinks, a short pause (LED off), another series of short
blinks, then a long pause (LED off). The first number in the LED code is the one, two, three or four blinks and the second
number is the second series of blinks before the long pause. If an OEM is using their own operator station that has no
LED, the codes will also be available on pin #7 of the 29 pin interface connector on the UII logic box.
Setup Parameter
Beginning of setup
Right Soft Limit
Left Soft Limit
Up Soft Limit
Down Soft Limit
Stow
Deploy
Monitor Orientation
Zero Position Sensors
Restore Factory defaults
Obstacle avoidance Disable
Obstacle Avoidance Manual Operation
Obstacle Avoidance Auto Operation
Obstacle Avoidance Learn
Stow rotation position
Electric Riser disable
Electric Riser enable
CAN Valve Disable
CAN Valve Enable
CAN Valve Pair
CAN Valve Calibrate
NOTES:
1. This step only needs to be done in two cases. If there is a position indicator in the system and/or the monitor is
mounted such that the physical rotational zero position is not in line with the physical center of the apparatus.
If needed, this step must be done first before setting ANY other positions. This setting will erase any previously set
positions including obstacle avoidance and stow/deploy.
2. These steps must be performed. The soft limits must be programmed so that the monitor stops before hitting a
hard limit. Hitting a hard limit will cause a sensor error code. If there is an active sensor error code, all soft limits and
automatic functions (stow/deploy, oscillation and obstacle avoidance) are ignored and the monitor will move
throughout its entire physical range with no restrictions which could cause collisions with the truck or truck
mounted obstacles.
3. These steps are optional and depend on the application needs.
4. Stow/Deploy position programming should be done after soft limits and obstacle avoidance (if used)
Blink Code
0-1 (One slow blink)
Programming Order (See Notes)
1-1
NOTE 2
1-2
NOTE 2
1-3
NOTE 2
1-4
NOTE 2
1-5
NOTE 4
1-6
NOTE 4
1-7
1-8
NOTE 1
1-9
2-1
2-2
NOTE 3
2-3
NOTE 3
2-4
NOTE 3
2-7
NOTE 4
3-1
3-2
4-1
4-2
4-3
4-4
Page 10
34405XXX Position Feedback Units