DOLD SAFEMASTER M 안전 기술 - 페이지 7

{카테고리_이름} DOLD SAFEMASTER M에 대한 안전 기술을 온라인으로 검색하거나 PDF를 다운로드하세요. DOLD SAFEMASTER M 12 페이지. Multi-function safety system

Function Diagrams
Note:
The times specified in a pulse diagram also apply to the same function in other applications.
supply
voltage
(A1/A2)
emergency stop 1,
contact 1 S12
emergency stop 1,
contact 2 S14
emergency stop 2
S22-S24
emergency stop 3
S32-S34
emergency stop 4
S42-S44
assigned
start button
enabling
LED en 1 en 2
output 48,
LED run 1
(error code)
2
output 58
(error)
: dark
: permanently
on
4 Emergency stop, Autostart; function: 4
supply
voltage
(A1/A2)
emergency stop 1,
S12-S14
emergency stop 2,
S22-S24
emergency stop 3,
S32-S34
emergency stop 4,
S42-S44
assigned
start button
enabling
LED en 1 en 2
output 48,
LED run 1
(error code)
2
output 58
(error)
: dark
: permanently
on
4 Emergency stop, manual start; function 5
2
2
2
: flashing code
2
: flashing code
: constant flashing
2
2
t<
250ms
2
2
7
2
3
t=
250ms
M9001_b
2
2
M9003_a