{카테고리_이름} DOLD SAFEMASTER M에 대한 안전 기술을 온라인으로 검색하거나 PDF를 다운로드하세요. DOLD SAFEMASTER M 12 페이지. Multi-function safety system
Function Diagrams
Note:
The times specified in a pulse diagram also apply to the same function in other applications.
supply
voltage
(A1/A2)
emergency stop 1,
S12-S14
emergency stop 2,
S22-S24
two-hand 1
S32-S34
two-hand 2
S42-S44
enabling of the other
modules assigned
to the same output
enabling
LED en 1 en 2
output 48,
LED run 1
(error code)
output 58
(error)
t<
0,
5s
: dark
: permanently
on
2 Emergency stop, Autostart, 1 two-hand control type IIIC; function: 6
supply
voltage
(A1/A2)
emergency stop 1,
S12-S14
emergency stop 2,
S22-S24
two-hand 1
S32-S34
two-hand 2
S42-S44
enabling of the other
modules assigned
to the same output
assigned
start button
enabling
LED en 1 en 2
output 48,
LED run 1
(error code)
output 58
(error)
: dark
: permanently
on
2 Emergency stop, manual start, 1 two-hand control type IIIC; function: 7 or 9
2
: flashing code
: constant flashing
2
: flashing code
: constant flashing
2
2
2
8
3
t=
0,5s
M9005_a
M9007_a
07.10.15 en / 477