The Cypress SPX-5600 provides additional data channels to support access control hardware such as door strikes, tamper
alarms, request to exit status, etc. These signals are sent to and from the Remote and Central units without the need to run
additional wiring.
The accessory control I/O use active low inputs. When the inputs are floating (nothing connected) the associated output will be
set to a high level. When the input is set to 0Volts (Ground) the input will activate its associated output. All Accessory outputs
are Open Collector type and will switch to Ground when activated.
Each input will have an associated output. See the following pages for a diagram of each I/O pair.Inputs can be tested by
making a jumper connection to ground and monitoring the associated output.
Suprex RF Central
Suprex RF Remote
Page 11 of 20
Cypress Suprex 5600 Series - Door Strike and LED I/O
Input
LED In
Jumper to ground to test
Ground
Red arrow denotes direction of command signal
Output
LED Out