FAULT-TRACING PROGRAM

The fuctions of the elctrical components can be tested:
Press S6 five times.
Press S2 for inlet valve 2.
Press S3 for inlet valve 1.
Press S4 for combi doser.
Press S5 for the heating element
Press S6 for the circulation pump.
Press S7 for the outlet pump.
Press S8 for fan motor and vax motor.
Stop the fault-tracing program by pressing S13 on DW 954 / 955, or one of the
program buttons for 3 seconds on DW 953.

WATER HARDNESS SETTING (just machines with softener).

Press S7 five times within 15 seconds.
Press S2 for a water hardness of
"
S3
"
S4
"
S5
"
S6
"
S7
"
S8

COOL DOWN (Just DW955 without softener)

A Cool down period after the first pre-wash and main wash can be added on
cold water connected machines < 25°C, 77°F) and high wash temperatures
(< =65°C, 149°F).
Press S9 five times.
Press S5 to get cool-down or
press S4 to get normal temperature.

LINKS ON THE PROCESSOR BOARD (for program variations)

Link 953: DW953 processor board layout
Link 955: DW955, processor board layout.
Link Europe: Europa processor board layout.
Link USA: USA processor board layout.
Link Soft: Machine with softener
Link SSP: Quick wash is replaced by "Pika Pesu" = a cold program,
15 minutes long.
Link 230V: Machine for 230V (hardware).
DW 953, 954, 955, 95FI
"
"
"
"
"
"
0–9
°dH
10–14
"
15–19
"
20–24
"
25–34
"
35–49
"
50–70
"
Normal setting