DOOR SWITCH
A microswitch senses that the door has been opened. This interrupts the
program and cuts the power to all control components (motor, valves etc.).
LEVEL SWITCH
The level switch provides protection against overfilling, interrupting the power to
the inlet valve and starting the outlet pump.
If the water level has not dropped within 30 seconds or if overfill has
occurred twice during the same program, the program will be terminated
The overfill protection operates during all programs, including fault-tracing, and
even if the microprocessor is faulty.
OVERFILL SWITCH
A float influences a micro switch which disconnects the inlet valve and starts
the outlet pump. Function: See "Level switch" above.
COMBI DISPENSER
The combi dispenser doses both detergent and rinse aid
In the doser there is an adjustable volume chamber for setting of the
desired amount of rinse aid.
On certain models there is a sensor for rinse aid level mounted on the doser.
MAIN SWITCH
The main switch is a 2-pole switch, interrupting both the phase and neutral
supplies.
ELECTRICAL CORD
The machines are fitted with 3xl ,0mm2 connection cords and earthed plugs.
Variations occur for different markets.
ELECTRICAL SUPPLY
As delivered , the machines are wired for connection to a single-phase, 230 V,
10 A supply, with a heater power of 1800 W, giving a total power requirement
of 2000 W.
Alternative: single-phase, 230 V, 16 A, heater power 3000 W total power
requirement 3200 W
Altemative: 2-phase, 400 V, 10 A, heater power 3000 W total power
requirement 3200 W.
SOFTENER
If softener is used, link "Soft" must be taken away from the control unit. This
means connecting of the softener valve. On certain models sensor for rinse
aid level is mounted on the softener. This indicates by lack of salt .
DW 953, 954, 955, 95FI