Ambifuego KALIDO77 사용자, 설치 및 서비스 지침 - 페이지 14

{카테고리_이름} Ambifuego KALIDO77에 대한 사용자, 설치 및 서비스 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Ambifuego KALIDO77 16 페이지.

USER INFORMATION
With the control knob at the highest setting, rotate in a clock-wise
direction towards the lower setting as required.
The appliance is now operating at lower operating output.
Extinguishing the appliance back to permanent pilot
setting
Extinguishing the appliance fully
In the extent of a flue blockage or spillage, the monitoring system will
operate and turn off the fire. If this occurs extinguish the appliance
fully and re-light following the procedures as previously described.
If the fire repeatedly shuts down by the monitoring system, then a
specialist engineer should be informed.
From any heat setting, turn the
Control
knob
in
a
clockwise
direction to the "Pilot" position.
From any heat setting, turn to
"Pilot" as in "Extinguishing the
appliance back to permanent pilot
setting".
Depress the control knob slightly
and turn clockwise to "Off" position.
14
INSTALLER INFORMATION
Testing and Commissioning
Turn on and test the gas supply up to the fire for any leaks, in
accordance with current edition of BS6891.
Test the setting pressures as detailed on page **.
Perform a spillage test as detailed on page **.
When the appliance is first used, the coating of various parts may
cure. It is advisable to ventilate the room during this period for at
least one hour.
19