Ambifuego KALIDO77 사용자, 설치 및 서비스 지침 - 페이지 6

{카테고리_이름} Ambifuego KALIDO77에 대한 사용자, 설치 및 서비스 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Ambifuego KALIDO77 16 페이지.

GENERAL INFORMATION

General Fitting Information

Inlet Pipe connection
8mm Compression
Flame monitor
Permanent Pilot
Appliance mass
5kg
User control: Variable rotary control inc. integrated Piezo ignition,
Permanent pilot facility, Flame failure device and TTB flue blockage
Cut-out.
Before installation of these appliances, the area into which the fire is
to be fitted must be cleared of all debris (including dust), in particular
combustible material.
The appliance must sit on a hearth (or base surface) sufficient to
support the weight of the fire. The burner must then also be secured.
Brackets are supplied for this purpose.
The flue must be connected to only one fireplace, and the flue must
not vent more than one appliance (i.e. not shared with a gas back
boiler). There must be no opening in the flue apart from the one that
the appliance is installed into, and the one venting the gases into the
air. A suitable terminal may be fitted, such as class GC1, as
regulations allow.
Any flue damper plates or flue restrictors shall be removed or fixed
permanently in the fully open position.
The chimney must be swept before the appliance is installed and a
flue test in accordance with national regulations carried out.
This appliance has been tested for use with circular flues of a
minimum internal diameter of 125mm (5").
The flue termination (cowl) must be of a type suitable for use with an
inset Decorative Fuel Effect Fire BS5871 part 3 contains further
details.

Battery type (Remote Versions only)

Receiver: 4x AA, R6 size.
Transmitter: PP3 (Alkaline only).
6
INSTALLER INFORMATION
Servicing Instructions
Ensure that the fire is fully cold before attempting service. A
suggested procedure for servicing is detailed below.
1. Lay out the dust sheet and tools.
2. Inspect the area around the top of the fireplace opening for signs
of spillage.
3. Carefully remove the ceramic components. Use a soft brush to
clean off ceramics, the use of a vacuum cleaner directly on the
ceramics is not recommended. Replace any broken ceramics.
4. Carefully remove the Grate, clean the grate and the top of the
burner, a vacuum cleaner and brush may be used.
5. Isolate the gas supply at the appliance inlet, and disconnect the
gas supply pipe.
6. Remove the screws securing the burner to the hearth.
7. Remove the burner unit from the fireplace opening.
6. Check the base of the fireplace opening for rubble accumulation
and remove. If debris is excessive, initiate remedial work on the flue.
7. Check the flue with smoke pellet for correct operation.
8. Strip off the burner pipes and clean thoroughly.
9. Clean out the injector and pilot assembly. DO NOT attempt to
dismantle the pilot unit.
10. Ensure the injector is aligned squarely in the injector bracket. Re-
assemble and re-fit the burner tray.
11. Re fit and replace the ceramics, using genuine spares where
necessary.
12. Turn on the gas supply, and leak test.
13. Check any purpose provided ventilation is un-obstructed.
14. Light the fire and test for spillage.
15. Check setting pressure and safe operation of the appliance.
27