INSTALLER INFORMATION
Spare Parts
Burner, Natural
Burner, LPG
Pilot Natural
Pilot LPG
Injector Assembly Natural (650 Marking)
Injector Assembly LPG (280 Marking)
Control Valve (Mertik)
Simple Remote
Climate Remote
Control Valve (Seagas)
To replace these items, follow the procedure listed in the servicing
instructions above.
XXxxxxx
XXxxxxx
XXxxxxx
XXxxxxx
XXxxxxx
XXxxxxx
XXxxxxx
XXxxxxx
XXxxxxx
XXxxxxx
28
GENERAL INFORMATION
Bearing in mind that the heat given off by this appliance may affect articles
placed close to it, curtains should not be placed within 30cm.
The appliance is not designed as a dryer. It is not therefore recommended
that the appliance be used in such a manner. Do not place any articles within
30cm of this appliance as this may result in damage to the articles.
The installation must be carried out in accordance with the following
regulations:
The Building Regulations issued by the Department of the Environment, the
Building Standards (Scotland) (Consolidation) Regulations issued by the
Scottish Development Department.
BS 1251, BS 5440 parts 1 & 2, BS 5871 part 2, BS 6461 part1, BS 6891 and
BS 8303
In the Republic of Ireland the installation must also conform to the relevant
standards, particularly in regard to flue sizing and ventilation. Refer to
documents IS813, ICP3, IS327 and any other rules in force.
This appliance must be installed in accordance with the rules in force and
used only in a sufficiently ventilated space, and is intended for use on a gas
installation with a governed meter.
Before installation, ensure that the local distribution conditions (identification
of the type of gas and pressure) and the adjustment of the appliance are
compatible. The technical specification of this appliance is given on the rear
page of this manual.
The fuel bed or this appliance should not be disturbed, and rubbish or other
fuels must not be thrown onto the fire.
The Chimney should be checked regularly to ensure that all the products of
combustion are entering the flue or canopy, and that there is no excessive
build up of soot. If any soot is found to build up it must be removed as
described in the servicing instructions.
Ventilation must be checked regularly to ensure that it is free from
obstruction.
5