Axial fan & heat exchanger
Step 1 Axial fan
Remove the 4 nuts securing the axial fan to the rear spinning
assembly.
Check that the fan spins freely without any sign of being out of
balance or bearing noise. If so replace the fan.
If fan operation appears fine, then with a soft brush remove dust
from the impellars and motor.
Replace the fan after checking the heat exchanger assembly.
Step 2 Heat exchanger assembly maintenance
Remove the screws fastening the front spinning to case assembly.
Using a soft brush remove any dust and dirt from the rigid tubes,
flexible coil and reflector gaining access front and rear of the
product. Inspect the tube assembly and if holes or internal
blockages are suspected either replace the at risk component by
removal of the heat exchanger assembly through the front of the
product or clear any blockage.
Refit the front spinning assembly.
Burner maintenance
Step 1
Remove the screws fixing the rear spinning to the case assembly
and the gas hose.
Step 2
Remove the bolts securing the rear support to the case assembly.
5