Step 3
Slacken the grub screw securing the burner to the firing tube.
Step 4
Remove the screws fixing the burner assembly to the case.
Step 5
6
MOBILE RADIANT HEATER
Slide the burner assembly away from the firing tube to reveal the
burner assembly.
Inspect the burner electrode assembly condition taking care when
reassembling to ensure that the leads to the assembly are fitted
the same way as on removal. If the electrode assembly is in good
order check the spark electrode gap. This should be
3.5mm + 0.5mm. Adjust the gap if necessary by bending the
earth rod.
Step 6
With a soft brush remove dust from the burner head filter.
If a blockage is suspected replace the filter by removing the ignitor
assembly and with a small screwdriver prise the filter from its
location.
Re-fit.
Step 7
Access to the injector is by removal of the screws that attach the
gas valve fixing plate to the burner assembly.
On removal of the screws and plate inspect the injector and clean
as necessary. Do not broach out.