MOS - UNO - IP
MANUAL

Remote device settings

Device:
Discription:
"" selected
Current setting
SUB-D only
Triggers only on SUB-D GPI
Axia Node
Connects to an Axia node
Axia QOR (16-32)
Connects to an Axia QOR-16 or QOR-32
DHD global logic
Listens to DHD global logics
Axia node:
Connects directly to the remote IP of an Axia node.
Axia QOR (16-32):
Connects directly to the remote IP of an Axia QOR-16 or QOR-32
On using GPI or GPO contacts on the QOR to trigger the MOS-UNO-IP, select Node as device.
On using the Axia livewire software driver the Node needs to be selected as device.
DHD global logics:
Listens to DHD global logics. Enter the DHD Toolbox project ID in the field of TCP command 1.
Enter the used global logic number (1 – 200) in the field of TCP command 2. See GPI settings for
details.
The webpage of the MOS-UNO-IP shows the connection status:
When a connection to a node or QOR has been disconnected the MOS-UNO-IP will try to
reconnect. On a longer connection timeout the webpage will show the link has been disconnected.
To restore the connection the MOS-UNO-IP has to be rebooted.
STEENWEG 148C - 9810 NAZARETH - BELGIUM - T +32 (0)9 396 76 40 - [email protected]