2000e & 2000eM Keypad Installation & Programming
Specifi cations
Parameter
Voltage Requirements
Keypad Current
Requirements (Max)
Keypad with Output
Expansion Module
(2000-8EX) Current
Requirements (Max)
Relay Contact Rating
REX Input
Door Position Switch Input
Mechanical Dimensions
Environment
Temperature Tolerance
Front End Cable Type
Front End Distance and
Wire Gauge
Firmware Version
Technical Support
DEALERS/INSTALLERS ONLY! End users must contact the
dealer/installer for support. If the keypad still does not work after
troubleshooting, please call the Technical Services department
at 1-800-421-1587.
6-104402 X2
Specifi cations
10-30 VDC; 12-24 VAC
VDC
VAC
10V: 85mA
12V: 150mA
30V: 115mA
24V: 200mA
VDC
VAC
10V: 230mA
12V: 500mA
30V: 390mA
24V: 700mA
Note: This is total maximum
current including keypad and
output module.
2A @ 30VDC (Main & Aux)
Normally Open Dry Contact
Normally Closed Dry Contact
4.50" H x 2.75" W x 0.60" D
Indoor or Outdoor
-31°F to 151°F (-35ºC to 66°C)
Stranded and Shielded
1000 Ft. – 18 AWG
500 Ft – 20 AWG
250 Ft. – 22 AWG
1.0x ("1" is the major version;
"0" is the minor version; "x" is
a minor version, reserved for
bug fi xes, which is indicated
with a letter, such as "a".)
Installation & Programming Instructions
Note: This product is designed to be installed and serviced
Keypad Operating Modes
The 2000e/2000eM keypad has three operating modes: Standalone
Mode, Secured Series Front End Mode and Wiegand Front End
Mode. Below is a brief explanation of each mode. Refer to the
programming section for details about selecting each mode.
Standalone Mode:
By default, the keypad is programmed for Standalone Mode. In this
mode, all the users and other programming options are maintained
within the keypad and no additional controller is required. The
lock and all other inputs and outputs are connected directly to the
keypad.
Secured Series Front End Mode:
In Secured Series Front End mode, a Secured Series Controller is
required. The Secured Series Controller maintains the users and
programming options and makes all the access control decisions.
The locking device and all inputs and outputs are connected to
the controller. The 2000e/eM keypads were evaluated by UL, in
Secured Series Front End mode, for use only with the Hub Max II
and Hub MiniMax II products.
Wiegand Front End Mode:
In Wiegand Front End mode, a separate Wiegand Access Control
panel is required. When you enter a code on the keypad it is then
sent to the control panel as Wiegand card data, depending on
which format you've programmed it for. The control panel maintains
the users and programming options and makes all the access
control decisions. The locking device and all inputs and outputs
are connected to the control panel. The 2000e/eM keypads were
evaluated by UL, in Wiegand Front End mode, for use only with the
Hub Max II and Hub MiniMax II products used in conjunction with
the Wiegand Interface Module.
Mounting the Keypad
The keypad is designed to be fl ush mounted using a standard UL
Listed single-gang electrical box. Mounting height can vary depending
on requirements. An appropriate range is typically between 48 and 52
inches on center off the fl oor.
For outdoor installations, use a UL Listed weatherproof back box and
seal the wire entry locations with silicone and provide a drain hole.
For additional protection, install the provided foam gasket between
the keypad and the back box. In addition, use the anti-oxidant grease
pack for the wire harness connectors.
2000e & 2000eM Keypad
by security and lock industry professionals.
1