Programming Keypad Parameters
(Default settings are in bold)
Command/Action
Change Keypad Parameters
Parameter
0 – Duress Output Duration
1 – Panic Output Duration*
2 – Error Lockout Threshold
3 – Error Lockout Duration
4 – Auto-Entry Count
7 – Auto-Entry Keypress
Timeout
10 – Wiegand Format
11 – Wiegand Pulse Width
12 – Wiegand Interpulse
Spacing
Note: Refer to the Wiegand Format Chart for parameter 8.
Change Wiegand Parameters
Parameter
0 – Wiegand Site ID
1 – Wiegand Group ID
Note: The default setting for both settings is 0.
*Note: The Panic Output is activated by pressing the ✱ and # keys
at the same time. This is used in case of emergency to activate an
auxiliary alarm device, such as a siren, that is used to indicate an
emergency condition only. This output should not be used to gain
access. All access control functionality should be programmed and
remain separate from the Panic Output functionality.

Resetting the Keypad

Note: This does not reset the keypad operating mode.
Command/Action
Reset Defaults Only
Reset Entire Keypad
6
Keys to Enter/Details
32 # parameter # value # ✱ ✱
Value
1 – 255 Seconds (default = 5)
1 – 255 Seconds (default = 5)
1 – 50 Attempts (default = 3)
1 – 255 Seconds (default = 10)
2 – 10 Digits (default = 4)
2 – 15 Seconds (default = 2)
1 – 8 (default = 1, 26-Bit)
1 – 255 (default = 8, 160μS)
1 – 255 (default = 32, 640μS)
34 # parameter # value # ✱ ✱
Value
Refer to Wiegand Format Chart
Refer to Wiegand Format Chart
Keys to Enter/Details
40 # 00000 # 00000 # ✱ ✱
46 # 00000 # 00000 # ✱ ✱
2000e & 2000eM Keypad Installation & Programming
Wiegand Format Chart
The keypad supports the following Wiegand formats (parameter 10).
Format
Wiegand
Value
Format
1
26 bit
2
28 bit
3
29 bit
4
30 bit
5
31 bit
6
32 bit
7
36 bit
8
29 bit
Wiegand Data
When the keypad is confi gured in Wiegand mode, the keypad data is
sent as a complete Wiegand data packet, as though you presented a
card.
For example, when programming a user into an Door Control Module,
you must program the user as though you were programming a card.
After entering the command to program a card user, enter the code
on the 2000e/eM keypad to send the data to the controller.
Please refer to the Wiegand Interface Module instructions 6-065700,
the HubMax II Instructions 6-065034 and the Hub MiniMax II
instructions 6-055037 for complete details.
LED/Sounder Indications
Indicator
Steady Red*
Steady Green*
Yellow Flashing Slowly
Solid Yellow
Alternating Red/Green
LED's Cycling Left to Right
LED's Cycling Right to Left
3 Rapid Beeps
Pair of Double Beeps
Single Double Beep
1 Long Beep, 1 Short Beep
1 Long Beep, 3 Short Beeps
1 Long Beep, 5 Short Beeps
6 Quick Beeps
Sounder ¼ sec on, ¼ sec off
Beep Every 2 seconds
*Note: The Red/Green LED descriptions above are for Standalone
and Secured Series Mode only. The operation of these LED's in
Wiegand Mode is determined by the LED control wire (brown) and
how it is confi gured. The LED control is confi gured using keypad
Options 19, 20, 21 and 22, which are programmed with Command 30.
Largest
Largest
PIN Value
Site Value
65535
255
32767
255
524287
255
65535
255
65535
255
8191
2047
999999
1023
524287
255
Description
Door Locked
Door Unlocked (timed or latched)
Program Mode
Program Error or Error Lockout
Awaiting 2nd PIN of Two-Part User
Over Voltage Warning
Under Voltage Warning
Invalid Code
User Lockout Activated
User Lockout Canceled
Access Denied, User Disabled
Access Denied, User Lockout
Access Denied, Code Mismatch
Toggle Mode Activated
Audio Alert 1
Audio Alert 2
6-104402 X2
Largest
Group
Value
N/A
N/A
N/A
15
31
63
N/A
N/A