BASIC SERVICE INSTRUCTIONS
PLEASE READ AND UNDERSTAND
REMOVING THE PRESSURE BAR FOR EASIER SERVICING
You can remove the pressure bar for easier servicing by simply removing The
Pressure Bar Bolts. Do not use any tools to hold the Pressure Bar Rods as they
may be damaged. They can only be held from the flat spots at the top of the rod.
When re-installing, please make sure to:
1) Remove the air pressure to the Vacuum Sealer.
2) Push the Nozzle inside the Nozzle Enclosure.
3) Lower the Cylinder rods on each sides
4) Re-install the Pressure Bar making sure there is an internal tooth washer
between the Pressure Bar and the Cylinder Rod, and another on top
against the head of the Bolt.
To order spare parts go to www.AmeriVacS.com and click on "Shop Online" then
THE HEATING ELEMENT (Part No. E- and T-)
Remove the broken Heating Element:
1) Remove 1½" Teflon that covers the old Heating Element.
2) Remove thumb nuts and washers from both sides. Remove Heating
Element.
3) Remove ½" Teflon that was under the Heating Element.